The first steps of this lesson
Step 1: What Safety Glazing Means and Who Marks It
The 2025 California Building Code (CBC) Section 2406.1 requires glazing in the hazardous locations of Section 2406.4 (including mirrors, single panes, laminated glass, and the panes of a multipane unit) to pass the impact test in Section 2406.2: CPSC 16 CFR Part 1201, Category II unless Table 2406.2(1) says otherwise. Each pane of safety glazing must carry a permanent designation (acid etched, sand blasted, ceramic fired, laser etched, or embossed, or a label) naming who applied it and the standard it meets (Section 2406.3). A replacement pane has to meet the same rules as new work (Section 2402.1), so a broken lite in a hazardous location is replaced with safety glazing.
Step 2: The Four-Part Window Test (CBC 2406.4.3)
An individual fixed or operable window pane is a hazardous location only if ALL four are true: the exposed area is greater than 9 sq ft, the bottom edge is less than 18 in above the floor or walking surface, the top edge is greater than 36 in above it, and a walking surface is within 36 in, measured horizontally in a straight line, of the glass plane. Fail any one test and 2406.4.3 does not apply. Exceptions: decorative glazing; a horizontal rail 34 to 38 in above the walking surface that withstands 50 lb per ft without touching the glass and is at least 1-1/2 in tall; and outboard panes of insulating units whose bottom edge is 8 ft or more above any adjacent grade or walking surface.
The remaining 3 steps, the worked example and the quiz are in the course. This is a preview. The full lesson, with the step-by-step explanations, a worked example and a quick-check quiz, is inside the classroom.
Independent exam preparation. Contractors Classroom is not affiliated with the Contractors State License Board, and no course can guarantee a passing result.