The first steps of this lesson
Step 1: Fume Limits Are Written as Numbers
Title 8 does not just say "keep fumes low." 8 CCR Section 5155, Table AC-1 lists a permissible exposure limit (PEL) for each airborne contaminant. The rows a welder meets most often are: welding fumes, total particulates, 5 mg/m3 (the table adds "see also individual constituents"); manganese fume, 0.2 mg/m3 (short-term limit 3 mg/m3); zinc oxide fume, 5 mg/m3 (short-term limit 10 mg/m3); iron oxide fume, 5 mg/m3; and cadmium oxide fume, 0.005 mg/m3. Hexavalent chromium has its own rule, 8 CCR Section 1532.2(c): 5 micrograms per cubic meter as an 8-hour TWA.
Step 2: The Time-Weighted Average Formula
The PEL is an 8-hour time-weighted average (TWA). The Appendix to Section 5155 gives the formula: TWA = (C1T1 + C2T2 + ... + CnTn) / 8, where C is the concentration during each period and T is the duration in hours. The note under the formula is easy to miss: "Eight (8) is used as denominator regardless of total hours of workday." A 10-hour shift is still divided by 8, so overtime pushes the TWA up.