The first steps of this lesson
Step 1: Lath Must Be Corrosion-Resistant and Rigidly Backed
The 2025 California Building Code (CBC) 2510.4 says metal lath and lath attachments shall be of corrosion-resistant material, and 2510.5 says the backing or lath shall provide enough rigidity to permit plaster application. Where lath on a vertical surface runs between rafters or similar projecting members, CBC 2510.5.1 requires solid backing for the lath and its attachments. Wire backing is not required under expanded metal lath or paperbacked wire fabric lath (2510.5.3). Gypsum lath or gypsum wallboard is not allowed as the backing for cement plaster (2510.5.2.1), with an exception for self-furred metal lath or wire fabric lath over a water-resistive barrier on ceilings, roof soffits and interior walls.
Step 2: Fastener Type and Spacing on Wood Framing
The 2025 California Residential Code (CRC) R703.7.1 says lath is attached with 1 1/2-inch-long, 0.120-inch-diameter, 11-gage nails having a 7/16-inch head, or 7/8-inch-long, 16-gage staples. They are spaced not more than 7 inches on center along framing members or furring, and not more than 24 inches on center between framing members or furring, or as otherwise approved. Additional fastening between wood framing members is not prohibited. Where exterior plaster serves as wall bracing under Table R602.10.4, the lath is attached directly to framing. Lath attachment to cold-formed steel framing or to masonry, stone or concrete follows ASTM C1063.
The remaining 3 steps, the worked example and the quiz are in the course. This is a preview. The full lesson, with the step-by-step explanations, a worked example and a quick-check quiz, is inside the classroom.
Independent exam preparation. Contractors Classroom is not affiliated with the Contractors State License Board, and no course can guarantee a passing result.