The first steps of this lesson
Step 1: What a Trap Seal Is
A trap seal is the standing water held inside a P-trap's bend. That water plug is what physically blocks sewer gas from traveling back up through the fixture into the room. It is not decorative plumbing shape - the water itself IS the barrier, and if it evaporates, siphons out, or gets pushed out, the barrier is gone even though the pipe looks fine.
Step 2: The Seal Depth Rule: 2 to 4 Inches
Per Section 1005.1, each fixture trap must have a liquid seal of not less than 2 inches and not more than 4 inches, except where the Authority Having Jurisdiction requires a deeper seal for a special condition. Too shallow and ordinary evaporation or a strong draft can break the seal; too deep and the trap won't self-scour properly.
Step 3: One Trap Per Fixture, One Trap Per Trap Arm
Each plumbing fixture must be separately trapped (Section 1001.2) - no double-trapping one fixture, and not more than one trap on a single trap arm. Exceptions exist for a set of up to three single-compartment sinks or lavatories that can share one trap if they're close together (waste outlets within 30 inches) and the trap sits centrally.
The remaining 2 steps, the worked example and the quiz are in the course. This is a preview. The full lesson, with the step-by-step explanations, a worked example and a quick-check quiz, is inside the classroom.