The first steps of this lesson
Step 1: Seismic Strapping - CPC 507.2
Water heaters in California must be strapped, blocked, or otherwise secured against horizontal displacement from earthquake motion, per CPC Section 507.2. In practice this means two seismic straps: one in the upper third of the tank and one in the lower third, anchored into structural framing - never into drywall alone.
Step 2: T&P Relief Valve and Its Discharge Pipe - CPC 608
Every water heater needs a temperature-and-pressure (T&P) relief valve to vent excess heat or pressure before the tank can fail. The discharge pipe from that valve must run to an approved point outside the structure (or an approved indoor termination), and it must NOT terminate into the water heater's own drain pan - the pan only catches leaks, it isn't rated to handle a full relief discharge.
Step 3: Garage Protection: Ignition Source Height and Impact Protection
A gas water heater installed in a garage needs its ignition source (burner/pilot) elevated a minimum of 18 inches above the garage floor, so it sits above the level where flammable vapors from parked vehicles can pool. Separately, if the water heater is subject to vehicle impact, it also needs physical protection such as bollards.
The remaining 2 steps, the worked example and the quiz are in the course. This is a preview. The full lesson, with the step-by-step explanations, a worked example and a quick-check quiz, is inside the classroom.