Gas Supply at the Home Site: Demand, Burial, Valves and Air Test
"Gas Supply at the Home Site: Demand, Burial, Valves and Air Test" is lesson 5 of 6 in the Manufactured Housing (C-47) Learning Hub. It opens with "Where the Rules Are" and works through 5 short steps, then a worked example you can check yourself against.
One-time purchase, no subscription. Law & Business included.
Steps in this lesson
Where the Rules Are
The Site Outlet, Conduit and Shutoff Valve
Meters, Burial and Materials
Demand and Pressure
Connect and Test the Home
The worked example in the course applies this lesson to a realistic job in 6 steps, from "Single site outlet" through "Test the home piping".
What you'll be able to do
Explain the main idea of "Gas Supply at the Home Site: Demand, Burial, Valves and Air Test" in plain language you can use on the exam.
Apply this step with confidence: "Meters, Burial and Materials".
Apply this step with confidence: "Demand and Pressure".
Apply this step with confidence: "Connect and Test the Home".
Test yourself on the worked example and the quick-check quiz inside the classroom.
The diagram for this lesson, exactly as it appears in the Learning Hub.
The first steps of this lesson
Step 1: Where the Rules Are
16 CCR 832.47(b) lets a C-47 contractor connect gas to the home on a single-family individual site. The 2025 California Mechanical Code Appendix D, Fuel Supply for Manufactured/Mobile Home Parks, prints the site rules. Like the plumbing appendix, it is not mandatory unless adopted by a state agency or referenced in the adopting ordinance. D 101.1 says gas piping serving manufactured homes is designed and constructed per CMC Chapter 13 or NFPA 54 and 58, so pipe sizing itself is a Chapter 13 matter; this lesson covers what Appendix D prints.
Step 2: The Site Outlet, Conduit and Shutoff Valve
D 101.3: the gas supply to the home is located within 4 feet of the home stand (with an exception for permanent foundations built to the local building code). D 102.1.1: underground gas piping may not run beneath the part of a site reserved for the home unless it is in an open-ended gastight conduit. D 102.1.2: the conduit is at least Schedule 40, its inside diameter is at least 1/2 inch larger than the gas pipe outside diameter, it extends at least 4 inches beyond the outside wall, and its outer ends are not sealed. D 103.2: a listed shutoff valve upstream of the site outlet, on the riser at least 6 inches above grade, never under the home, with a cap or plug on the outlet when no home is connected.