Refrigerant Charge Limit for a Room: RCL from CMC Table 1102.3
"Refrigerant Charge Limit for a Room: RCL from CMC Table 1102.3" is lesson 1 of 8 in the Refrigeration (C-38) Learning Hub. It opens with "What the Concentration Limit Protects" and works through 5 short steps, then a worked example you can check yourself against.
One-time purchase, no subscription. Law & Business included.
Steps in this lesson
What the Concentration Limit Protects
Read the RCL in Table 1102.3
Choose the Volume That Counts
Turn the RCL Into a Pound Limit
When the Circuit Is Over the Limit
The worked example in the course applies this lesson to a realistic job in 7 steps, from "Check the refrigerant and occupancy" through "Institutional comparison".
What you'll be able to do
Explain the main idea of "Refrigerant Charge Limit for a Room: RCL from CMC Table 1102.3" in plain language you can use on the exam.
Apply this step with confidence: "Choose the Volume That Counts".
Apply this step with confidence: "Turn the RCL Into a Pound Limit".
Apply this step with confidence: "When the Circuit Is Over the Limit".
Test yourself on the worked example and the quick-check quiz inside the classroom.
The diagram for this lesson, exactly as it appears in the Learning Hub.
The first steps of this lesson
Step 1: What the Concentration Limit Protects
A leak in a closed room can displace air or build to a toxic or flammable level. 2025 CMC Section 1104.2 therefore says that in a complete discharge of one independent circuit of a high-probability system, the concentration may not exceed the amount shown in Table 1102.3, called the Refrigerant Concentration Limit (RCL). A system is high-probability when a leak from a failed connection, seal or component will enter the occupied space (Section 1103.2.1); a direct system is the typical example. An indirect closed system is typical low-probability (Section 1103.2.2).
Step 2: Read the RCL in Table 1102.3
Table 1102.3 prints each refrigerant's safety group, OEL in ppm and RCL in lb/Mcf. Mcf is 1,000 cubic feet, so lb/Mcf is pounds of refrigerant per 1,000 cu ft of room. Printed RCL values: R-22 = 13, R-134a = 13, R-404A = 31, R-410A = 26, R-507A = 32, R-744 (carbon dioxide) = 3.4, R-290 (propane) = 0.59. Ammonia R-717 appears as 0.014, but the table note says ammonia systems are not regulated by Chapter 11 (Section 1102.2 sends them to the IIAR standards).
The remaining 3 steps, the worked example and the quiz are in the course. This is a preview. The full lesson, with the step-by-step explanations, a worked example and a quick-check quiz, is inside the classroom.